DACS Commands
List of commands to verify connection to equipment:

 

ECS1 and CS1:

     UTL QRY ALM

  To retrieve link on the ECS1 or CS1:

        DISPLAY LINK x  (

 

DACS II

       UTL::QRY,ALMS

  To retrieve link on the DACS II

         UTL::QRY,STR,LINK x
         (replace "x" for link number you are connected to 1-6)

 

DACS III and DACS IV

       RTRV-ALM-ALL::ALL;

   To retrieve link on the DACS III and DACS IV

       RTRV-SECU-LINK::LINK-x;
       (Replace the "x" with the link you are connected to)

 

Alcatel 16xx

       RTRV-ALM-ALL;

   To retrieve link on Alcatel

       RTRV-CID::cid;  

       (Replace "cid" for link you are connected to)


 

LUCENT DACS SETUP Parameters (Texas)

lucent dacs’, 3-0 and 3-1 dacs  with an id from att of dacsiv and dacsii

 

Lines-24;

columns-80;

reverse video-no;

screen saver-no;

scrolling-jump;

labels-on;

key click-off;

warning bell-on;

font size-large;

speed-9600;

stop bits-1;

data bits-7;

send parity-even;

check parity-yes;

echo-off;

encoding-off       

   


                                                                                                                                                     